12 17,5 24kV Pemutus Sirkuit Vakum Jero rohangan, Séri GPVN-E
Kaayaan Ambient
Suhu ambient: -25 ℃ ~ + 45 ℃, rata poean: ≤35 ℃
Luhurna: 1000m (Standar);bisa nepi ka 4500m pikeun susunan husus;
kalembaban relatif: poean rata ≤95%, bulanan rata ≤90%;
Inténsitas gempa ≤8 derajat;
Kasempetan lumaku kudu bébas tina inflammables, bahan peledak, corrosives jeung Geter parna.
Modél
GPVN -12Kv/17.5kV Indoor AC Tegangan Tinggi Pemutus Sirkuit Vakum
Spésifikasi teknis
No. | Barang | Unit | Data | ||||||
1 | tegangan dipeunteun | kV | 7.2~12(15/17.5) | ||||||
2 | Frékuénsi dipeunteun | Hz | 50/60 | ||||||
3 | Dipeunteun ayeuna | A | 630.1000.1250 | 1600 | 2000.2500.3150 | 4000 | |||
4 | Dipeunteun pondok-circuit megatkeun ayeuna | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
5 | Dipeunteun pondok-circuit nyieun ayeuna | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
6 | Dipeunteun pondok-waktu tahan ayeuna | kA | 20 | 25 | 31.5 | 31.5 | 40 | 40 | 50 |
7 | Dipeunteun puncak tahan ayeuna | kA | 50 | 63 | 80 | 80 | 100 | 100 | 125 |
8 | Dipeunteun pull-kaluar megatkeun arus | kA | 12.6 | 12.6 | 16 | 16 | 20 | ||
9 | Dipeunteun kaluar-of-fase earthing sesar megatkeun arus | kA | 17.4 | 21.7 | 27.4 | 27.4 | 34.7 | 34.7 | 43.5 |
10 | Dipeunteun pondok-circuit megatkeun ayeuna megatkeun waktu | Kali | 50 | 30 | 30 | 12 | |||
11 | Runtuyan operasi dipeunteun | O-0.3s-CO-180s-CO | O-180s-CO-180s-CO | ||||||
12 | Dipeunteun megatkeun ayeuna bank kapasitor tunggal | A | 630 | ||||||
13 | Dipeunteun megatkeun arus balik ka tukang kapasitor bank | A | 400 | ||||||
14 | 1 mnt.Frékuénsi kakuatan tahan tegangan | kV | Fase ka fase/ ka bumi: 42, sakuliah kontak kabuka:48 | ||||||
15 | Impuls kilat tahan tegangan | kV | Fase ka fase/ ka bumi: 75, sakuliah kontak kabuka:85 | ||||||
16 | Kahirupan mékanis | Kali | 20000 | ||||||
17 | waktos nutup | ms | ≤75 | ||||||
18 | Waktu muka | ms | ≤60 | ||||||
19 | waktos neundeun kakuatan dina tegangan dipeunteun | s | ≤10 |
Outline Dimensi GPVN-12E
GPVN-24□ Jero rohangan AC tegangan tinggi vakum circuit breaker
Spésifikasi Téknis
No. | Barang | Unit | Data | |||
1 | tegangan dipeunteun | kV | 24 | |||
2 | Frékuénsi dipeunteun | Hz | 50/60 | |||
3 | Dipeunteun ayeuna | A | 630 1250 1600 2000 2500 3150 4000 | |||
4 | Dipeunteun pondok-circuit megatkeun ayeuna | kA | 20 | 25 | 31.5 | 31.5 |
5 | Dipeunteun pondok-circuit nyieun ayeuna | kA | 50 | 63 | 80 | 80 |
6 | Dipeunteun pondok-circuit tahan ayeuna (4s) | kA | 20 | 25 | 31.5 | 31.5 |
7 | Dipeunteun puncak tahan ayeuna | kA | 50 | 63 | 80 | 80 |
8 | Dipeunteun kaluar-of-hambalan megatkeun arus | kA |
|
| 12.6 | 12.6 |
9 | Dipeunteun megatkeun arus kaluar-of-fase sesar bumi | kA | 17.4 | 21.7 | 27.4 | 27.4 |
10 | Dipeunteun kali megatkeun arus pondok-circuit megatkeun | Kali | 50 | |||
11 | Dipeunteun runtuyan operasi |
| O-0.3s-CO-180s-CO | |||
12 | Dipeunteun megatkeun ayeuna bank kapasitor tunggal | A | 630 | |||
13 | Dipeunteun megatkeun arus balik-ka-balik kapasitor bank | A | 400 | |||
14 | 1 mnt.Frékuénsi kakuatan tahan tegangan | kV | 50 | |||
15 | Impuls kilat tahan tegangan | kV | 125 | |||
16 | Kahirupan mékanis | Kali | 20000 | |||
17 | waktos nutup | ms | 75 | |||
18 | Waktu muka | ms | 60 | |||
19 | waktos Panyimpenan dina tegangan dipeunteun | s | 10 |