12/24/40.5kV Majelis Jepret Jeung Interlocking
Majelis jepret 5GP.320.010 diagram instalasi
(800mm rubak tengah-ditempatkeun switchgear)
Rapat Majelis 5GP.320.010 Daptar Susunan
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
1 | bracket ngarojong katuhu | 8GP.123.011 | 1 |
2 | plat sambungan katuhu | 5GP.235.011 | 1 |
3 | Nunjukkeun tag | 8GP.866.014 | 1 |
4 | sambungan kénca | 5GP.235.010 | 1 |
5 | Kénca ngadukung bracket | 8GP.123.010 | 1 |
6 | Sambungan las | 5GP.174.016.1(Pikeun VD4) | 2 |
5GP.174.016.2(Pikeun GPVN) | |||
5GP.174.016.3(Pikeun VB2) | |||
7 | Turun panto panto | 8GP.320.010 | 1 |
8 | Blok macet 8 | DK-8 | 8 |
9 | piring bracket | 8GP.123.013 | 3 |
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
10 | Sambungan las | 5GP.174.017.1(Pikeun VD4, 40kA) | 2 |
5GP.174.017.2(Pikeun VD4, 31.5kA) | |||
5GP.174.017.3(Pikeun GPVN) | |||
5GP.174.017.4(Pikeun VB2) | |||
11 | Nunjukkeun tag | 8GP.866.012 | 1 |
12 | Nunjukkeun tag | 8GP.866.013 | 2 |
13 | piring bracket | 8GP.123.012 | 3 |
14 | Jepret luhur | 8GP.320.011 | 1 |
15 | Panungtun rod | 8GP.234.011(Pikeun VD4, GPVN) | 2 |
8GP.234.011.1(Pikeun VB2) | |||
16 | Lengan stopper | 8GP.210.011 | 2 |
spésifikasi séjén daptar susunan jepret
Kodeu | 5GP.320.010.1 | 5GP.320.010.2 | 5GP.320.010.3 | 5GP.320.010.4 | 5GP.320.010.5 |
Lebar kabinét | 650 mm | 700 mm | 840 mm | 900 mm | 1000mm |
Gerbang luhur | 8GP.320.011.1 | 8GP.320.011.2 | 8GP.320.011.3 | 8GP.320.011.4 | 8GP.320.011.5 |
Gerbang handap | 8GP.320.010.1 | 8GP.320.010.2 | 8GP.320.010.3 | 8GP.320.010.4 | 8GP.320.010.5 |
Majelis jepret 5GP.320.011
(1000mm rubak tengah-ditempatkeun switchgear)
Alat mékanisme jepret 5GP.320.011 Daptar Susunan
(1000mm rubak tengah-ditempatkeun switchgear)
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
1 | bracket ngarojong katuhu | 8GP.123.276 | 1 |
2 | plat sambungan katuhu | 5GP.235.012 | 1 |
3 | Nunjukkeun tag | 8GP.866.014 | 1 |
4 | plat sambungan kénca | 5GP.235.013 | 1 |
5 | Kénca ngadukung bracket | 8GP.123.275 | 1 |
6 | Majelis las sambungan | 5GP.174.281 | 2 |
7 | Turun jepret | 8GP.320.273 | 1 |
8 | Blok macet 10 | DK-10 | 8 |
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
9 | piring bracket | 8GP.123.278 | 3 |
10 | Sambungan sambungan las | 5GP.174.282 | 2 |
11 | Nunjukkeun tag | 8GP.866.012 | 1 |
12 | Nunjukkeun tag | 8GP.866.013 | 2 |
13 | piring bracket | 8GP.123.277 | 3 |
14 | Jepret luhur | 8GP.320.274 | 1 |
15 | Panungtun rod | 8GP.234.272 | 2 |
16 | Lengan stopper | 8GP.210.011 | 2 |
spésifikasi séjén daptar susunan jepret
Kodeu | 5GP.320.011.1 | 5GP.320.011/JY | 5GP.320.011.2 | 5GP.320.011.3 |
Lebar kabinét | 800 mm | 1000mm (Isolasi) | 1100 mm | 1200 mm |
Gerbang luhur | 8GP.320.274.1 | 5GP.320.275 | 8GP.320.274.2 | 8GP.320.274.3 |
Gerbang handap | 8GP.320.273.1 | 5GP.320.275.1 | 8GP.320.273.2 | 8GP.320.273.3 |
Catetan: 5GP.320.275 nyaéta pikeun insulating jepret ku plat SMC di tengah jeung duanana tungtung ku plat baja, assembly jepret séjén lamun perlu insulating Gerbang mangga tangtukeun.
Earthing switch mékanisme operasi alat interlock (Pikeun operasi panangan drive sambungan) 5GP.363.010.1 diagram assembly
Parentah pikeun Alat Interlock
Alat interlock ditambahkeun interlock sabalikna jeung panto pungkur nu dirancang dina dasar 5GP.363.010 earthing switch mékanisme operasi aslina alat interlock.Hartina, sanggeus switch earthing ditutup sarta muka panto pungkur (sealing plate), interlock aslina masih bisa beroperasi switch earthing, tapi interlock ieu teu bisa.Anjeun mimitina kudu nutup panto pungkur (pelat sealing) guna beroperasi switch earthing.
Prinsip kerja tina alat interlock dirobah leungeun baju konci No.Nalika panto pungkur (pelat sealing) kabuka, leungeun baju konci asup kana liang kuadrat kabinet (dianjurkeun ukuran 35X35), switch earthing teu bisa dioperasikeun.
Alat interlock mékanisme operasi switch bumi (Pikeun operasi drive panangan sambungan)
5GP.363.010.1 daptar susunan.
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
1 | Bearing | 8GP.263.011 | 1 |
2 | Sektor | 8GP.192.010 | 1 |
3 | Sektor | 8GP.192.011 | 1 |
4 | Lengan sumbu | 8GP.210.014.1 | 2 |
5 | Sektor | 8GP.151.041 | 1 |
6 | Lengan sumbu | 8GP.211.061 | 1 |
7 | Sektor | 8GP.151.039 | 1 |
8 | Lengan sumbu | 8GP.211.062 | 1 |
9 | Baud M5 × 12 | GB70-85 | 1 |
10 | Sektor | 8GP.151.042 | 1 |
11 | Sektor | 8GP.151.043 | 1 |
12 | rod operasi | 8GP.200.013.1 (Long 1432 pikeun kabinét jero 1500 jero) | 1 |
8GP.200.013.2 (Long 1590 pikeun jero kabinét 1660) | 1 | ||
13 | piring ngarojong | 8GP.161.058 | 1 |
8GP.161.058.1(Pikeun pilihan) | 1 |
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
14 | Panutup | 8GP.017.011.1 | 1 |
15 | Kurung | 5GP.043.022 | 1 |
16 | piring ngarojong | 8GP.161.059 | 1 |
17 | Panggeser | 8GP.143.010 | 2 |
18 | Lengan sumbu | 8GP.211.058 | 1 |
19 | Lengan stopper | 8GP.211.057 | 3 |
20 | Dasar pangrojong | 8GP.043.019 | 1 |
21 | Tutup nuduhkeun | 8GP.866.010 | 1 |
22 | Majelis rod sambungan | 5GP.233.030.1 | 1 |
5GP.233.030.3(Pikeun pilihan) | 1 | ||
23 | Buka nunjukkeun | 8GP.866.011 | 1 |
24 | Ngonci leungeun baju | 8GP.211.201 | 1 |
25 | Plat colokan huntu | 8GP.151.044 | 1 |
26 | Lengan sumbu | 8GP.211.060 | 2 |
27 | Tag | 8GP.860.010 | 1 |
28 | Tekanan spring | 8GP.282.201 | 1 |
29 | Ngonci leungeun baju ngaropéa Bolt | 8GP.920.002 | 1 |
Catetan:
1. No 1~12 tingali kaca saméméhna.
2. No 22 Connection rod assembly, panangan sambungan boga dua ukuran: Kabinét puseur jarak 60mm di umum.Lamun perlu 80mm jarak puseur mangga parios kaca 17 instruksi assembly leungeun sambungan, sarta tangtukeun nalika mesen.
Alat interlock mékanisme operasi switch bumi (Pikeun operasi drive gear bevel) 5GP.577.1001
Earthing switch mékanisme operasi alat interlock (Pikeun operasi bevel gear drive) 5GP.577.1001 daptar susunan
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
1 | Bearing | 8GP.263.011 | 1 |
2 | Plat stopper | 8GP.151.084 | 2 |
3 | Lengan sumbu | 8GP.210.014.1 | 2 |
4 | Sektor | 8GP.151.041 | 1 |
5 | Lengan sumbu | 8GP.210.014.2 | 1 |
6 | Baud M 5X12 | GB70-85 | 1 |
7 | Sektor | 8GP.151.042 | 1 |
8 | Sektor | 8GP.151.043 | 1 |
9 | Lengan sumbu | 8GP.210.014.3 | 1 |
No. | Ngaran | Ngagambar No. | Qty.(pc/set) |
10 | Lengan stopper | 8GP.210.322 | 1 |
11 | rod operasi | 8GP.174.214 | 1 |
12 | Panutup | 8GP.017.011.2 | 1 |
13 | Dasar pangrojong | 5GP.043.022 | 1 |
14 | Panggeser | 8GP.143.010 | 2 |
15 | piring ngarojong | 8GP.161.059 | 1 |
16 | piring ngarojong | 8GP.161.058 | 1 |
17 | Plat colokan huntu | 8GP.151.044 | 1 |
18 | Tag | 8GP.860.010 | 1 |
Catetan: 1. mékanisme Ieu perlu interlocked kalawan handap panto, mangga tangtukeun nalika susunan.