GPR-24 (12) kV Series Ring Unit Utama Switchgear
Ringkesan
GPR-24 runtuyan Ring Unit Utama mangrupa extensible, SF6 insulated switchgear, kalawan tegangan dipeunteun tina 12 & 24 kV.Sadaya bagian hirup HV na dikandung dina tank gas kedap hawa, anu didamel tina stainless steel 3mm.Sakabeh assembly switching nyaeta SF6 insulated, sarta bébas tina sagala pangaruh éksternal, mastikeun eta reliabiliti hébat jasa jeung perawatan bébas.Ku plug-in tipe busbar extension, GPR-24 runtuyan Ring Unit Utama tiasa tina kombinasi bébas tur modularization pinuh.Ekstensi busbar parantos lulus uji jinis pikeun kakuatan sareng stabilitas termal, sareng pinuh insulasi sareng dilindungan, nunjukkeun réliabilitas sareng kaamanan anu luhur.GPR-24 séri Ring Unit Utama cocog pikeun sadaya jaringan MV nepi ka 24 kV, sadaya stasiun listrik kompak, gardu distribusi listrik dina sadaya industri penting, sapertos industri bensin-kimiawi, industri metalurgi sareng pertambangan, sareng sadaya gardu trafo sareng tenaga angin. sistem.
Fitur
1. Téhnik prosés canggih pikeun tanki gas
The digital-dikawasa motong laser sarta sistem punching sarta tilu diménsi jeung lima sumbu laser Sistim las diimpor ti Jerman kalawan mastikeun tightness gas sarta uniformity sadaya tanghi gas.
Sistem deteksi bocor hélium pinuh otomatis tur integral, dijieun ku SEILER Vakuumtechnik GmbH, ngaliwatan detecting of Hélium leakage ku spectrograph massa, brings laju leakage gas per taun ka handap pikeun kirang ti 0.02%, mastikeun span hirup tank gas leuwih 30 taun.
Téhnik prosés canggih pikeun bagian.
Kabéh résin epoxy bagian insulated, kaasup kutub insulated, dijieun ku pinuh-otomatis tur dikawasa digital epoxy résin vakum campur / tekanan sistem gelatinizing ti Hedrich (Jerman).
Konektor busbar, panyambung kabel, tungtung-colokan sareng bagian insulated karét silikon sanésna diproduksi ku sistem pencampuran karét silikon / tekanan gelatinisasi pinuh-otomatis sareng dikawasa sacara digital tina VOGEL (Swiss).
2. solusi alus teuing pikeun produk
Kalayan struktur leutik sareng kompak, unit fungsional dasar K, T, V, B sareng C gaduh dimensi seragam: 350 * 800 * 1380 mm (lebar * jero * jangkungna).
Solusi lengkep:
Vérsi tunggal: beban break Unit switch, switch-sekering Unit, vakum circuit breaker Unit, busbar Unit subsection, Unit kabel, Unit pangukuran, jsb
Versi blok tiasa diwangun ku dua, tilu, opat, lima atanapi genep unit fungsional.
Hijian tunggal jeung versi blok bisa disambungkeun ku konektor busbar flexibly.
3. adaptability kuat ka lingkungan
Sistim conductive primér pinuh disegel dina tanki gas SF6 sarta moal dipangaruhan ku lingkungan luar, bebas tina dampak embun, lebu, kabut uyah, jsb Ku alatan éta, runtuyan GPR-24 bisa dilarapkeun dina sagala rupa kaayaan jasa parna. .
Data Téknis 12kV
Katerangan | Unit | Unit LBS | Unit switch-sekering | Unit VCB | Unit sub-bagian busbar | |
tegangan dipeunteun | kV | 12 | 12 | 12 | 12 | |
Frékuénsi kakuatan tahan tegangan (1 mnt) | Fase ka fase/bumi | kV | 42 | 42 | 42 | 42 |
Meuntas jarak ngasingkeun | kV | 48 | 48 | 48 | 48 | |
Impuls tahan tegangan | Fase ka fase/bumi | kV | 75, (95)* | 75, (95)* | 75, (95)* | 75, (95)* |
Meuntas jarak ngasingkeun | kV | 85, (110)* | 85, (110)* | 85, (110)* | 85, (110)* | |
Frékuénsi dipeunteun | Hz | 50,60 | 50,60 | 50,60 | 50,60 | |
Dipeunteun ayeuna | A | 630 | ① | 630 | 630 | |
Dipeunteun pondok circuit megatkeun arus | kA |
| ② | 20,(25)* |
| |
Dipeunteun waktos pondok tahan ayeuna | kA/s | 20/3, (20/4, 25/1)* |
| 20/3, (20/4, 25/3)* | 20/3, (20/4, 25/1)* | |
Dipeunteun puncak tahan ayeuna | kA | 50, (63)* |
| 50, (63)* | 50, (63)* | |
Dipeunteun pondok circuit nyieun ayeuna | kA | 50, (63)* | ② | 50, (63)* | 50, (63)* | |
Dipeunteun mindahkeun ayeuna | A |
| 1800 |
|
| |
Dipeunteun beban aktif megatkeun ayeuna | A | 630 |
|
| 630 | |
Dipeunteun loop katutup megatkeun arus | A | 630 |
|
| 630 | |
5% dipeunteun beban aktif megatkeun ayeuna | A | 31.5 |
|
| 31.5 | |
Dipeunteun runtuyan operasi |
|
|
| O-0.3s-CO-180s-CO |
| |
Saumur hirup mékanis | Ops. | 5000 | 5000 | 10000 | 5000 | |
hirupna listrik |
| E3 |
| E2 | E3 | |
Ketebalan stainless steel | mm | 3.0 | ||||
Dipeunteun SF6tekanan | kPa | 30 (dina 20 ℃, 101.3kPa) | ||||
Laju bocor taunan | <0,02% | |||||
Tes perlakuan cai | 12kV 24 jam (dina 30 kPa handapeun cai) | |||||
Tes busur internal | 20kA 1s | |||||
Gelar panyalindungan | Tangki béngsin | IP 67 | ||||
Panyekel sekering | IP 67 | |||||
GPR dipager |
| IP 4X |
Data Téknis 24kV
Katerangan | Unit | Unit LBS | Unit switch-sekering | Unit VCB | Unit sub-bagian busbar | |
tegangan dipeunteun | kV | 24 | 24 | 24 | 24 | |
Frékuénsi kakuatan tahan tegangan (1 mnt) | Fase ka fase/bumi | kV | 50, (65)* | 50, (65)* | 50, (65)* | 50, (65)* |
Meuntas jarak ngasingkeun | kV | 64, (79)* | 64, (79)* | 64, (79)* | 64, (79)* | |
Impuls tahan tegangan | Fase ka fase/bumi | kV | 95, (125)* | 95, (125)* | 95, (125)* | 95, (125)* |
Meuntas jarak ngasingkeun | kV | 110, (145)* | 110, (145)* | 110, (145)* | 110, (145)* | |
Frékuénsi dipeunteun | Hz | 50, 60 | 50, 60 | 50, 60 | 50, 60 | |
Dipeunteun ayeuna | A | 630 | ① | 630 | 630 | |
Dipeunteun pondok circuit megatkeun arus | kA |
| ② | 20 |
| |
Dipeunteun waktos pondok tahan ayeuna | kA/s | 20/3, (20/4)* |
| 20/3, (20/4)* | 20/3, (20/4)* | |
Dipeunteun puncak tahan ayeuna | kA | 50 |
| 50 | 50 | |
Dipeunteun pondok circuit nyieun ayeuna | kA | 50 | ② | 50 | 50 | |
Dipeunteun mindahkeun ayeuna | A |
| 1400 |
|
| |
Dipeunteun beban aktif megatkeun ayeuna | A | 630 |
|
| 630 | |
Dipeunteun loop katutup megatkeun arus | A | 630 |
|
| 630 | |
5% dipeunteun beban aktif megatkeun ayeuna | A | 31.5 |
|
| 31.5 | |
Dipeunteun runtuyan operasi |
|
|
| O-0.3s-CO-180s-CO |
| |
Saumur hirup mékanis | Ops. | 5000 | 5000 | 10000 | 5000 | |
hirupna listrik |
| E3 |
| E2 | E3 | |
Ketebalan stainless steel | mm | 3.0 | ||||
Dipeunteun tekanan SF6 | kPa | 30 (dina 20 ℃, 101.3kPa) | ||||
Laju bocor taunan | <0,02% | |||||
Tes perlakuan cai | 24kV 24 jam (dina 30 kPa handapeun cai) | |||||
Tes busur internal | 20kA 1s | |||||
Gelar panyalindungan | Tangki béngsin | IP 67 | ||||
Panyekel sekering | IP 67 | |||||
GPR dipager | IP 4X |
Catetan:
① Dipeunteun ayeuna unit switch-sekering gumantung kana rating sekering: ≤100A
② Dipeunteun sirkuit pondok megatkeun / nyieun arus tina switch-sekering Unit gumantung kana rating sekering
* Nilai dina kurung pikeun sarat husus, mangga ngahubungan produsén atawa supplier pikeun émbaran leuwih lengkep
Ihtisar runtuyan GPR24
1. tipe tank tunggal
Catetan:
1. Nilai dina kurung ditandaan ku "*" mangrupakeun produk di 24kV, frékuénsi kakuatan tahan tegangan 65/79kV;